The PALEX Upright Type Sprinkler is an automatic fire suppression device designed for installation above branch piping, with the deflector positioned upward. It is specifically engineered for areas with exposed piping systems, high ceilings, warehouses, industrial facilities, and locations where ceiling-mounted pendent sprinklers are not practical.

Manufactured using high-quality corrosion-resistant materials and equipped with a heat-sensitive glass bulb, the upright sprinkler automatically activates when the surrounding temperature reaches its rated value. The upward-facing deflector distributes water in a carefully engineered spray pattern, ensuring effective fire suppression and protection of the designated coverage area.

The sprinkler is suitable for industrial buildings, warehouses, factories, commercial facilities, storage areas, parking structures, and other fire protection applications requiring dependable automatic fire suppression.

Speak to our fire safety expert to learn more about this product.

Product Description

1. General Data

ParameterDetails
ManufacturerPalladium Safety Solutions Pvt. Ltd.
BrandPALEX
Product TypeUpright Type Sprinkler
Installation TypeUpright Mounted
ApplicationAutomatic Fire Suppression Systems

2. Material & Construction Details

ComponentSpecification
Body MaterialCarbon Steel
Thermal ElementHeat-Sensitive Glass Bulb
Thread TypeNPT –" or R –"
Surface FinishCorrosion-Resistant Coating
Deflector TypeUpright Water Distribution Deflector

3. Technical Specifications

ParameterDetails
Operating Temperature Range57°C to 260°C
Response TypeStandard Response / Quick Response
Operating Pressure12 Bar
Maximum Service Pressure175 PSI (12.07 Bar)
Thread SizeNPT –" or R –"
Installation OrientationUpright
Glass Bulb TypeColour-Coded Thermal Bulb

Available Temperature Ratings

TemperatureBulb Colour
57°COrange
68°CRed
79°CYellow
93°CGreen
141°CBlue
182°CMauve
260°CBlack

4. Performance Specifications

ParameterDetails
Hydraulic Pressure CapacityUp to 175 PSI
Activation ResponseFast Thermal Activation
Spray PatternUniform Upright Distribution
Heat Detection AccuracyHigh Precision
Corrosion ResistanceExcellent
Service LifeLong-Term Use

5. Key Features

Upright Installation Design

  • Installed above branch piping.
  • Suitable for exposed pipe systems.
  • Ideal for industrial environments.

Automatic Fire Detection

  • Heat-sensitive glass bulb operation.
  • Automatic activation during fire conditions.
  • Reliable fire suppression response.

Multiple Temperature Ratings

  • Available for various environmental conditions.
  • Flexible fire protection design.
  • Application-specific performance.

Efficient Water Distribution

  • Optimized upward deflector design.
  • Uniform water coverage.
  • Effective fire suppression.

Durable Construction

  • Carbon steel body.
  • Corrosion-resistant finish.
  • Long operational lifespan.

Flexible System Integration

  • Compatible with standard sprinkler systems.
  • Suitable for new and retrofit installations.

6. Performance Benefits

Early Fire Suppression

The sprinkler helps:

  • Detect heat rapidly
  • Suppress fires at an early stage
  • Minimize fire damage

Reliable Fire Protection

Provides:

  • Continuous monitoring
  • Automatic activation
  • Consistent fire control performance

Enhanced Safety

Supports:

  • Occupant protection
  • Property protection
  • Reduced fire spread

7. Applications

Warehouses

  • Storage facilities
  • Logistics centres
  • Distribution hubs

Industrial Facilities

  • Manufacturing plants
  • Production units
  • Workshops

Commercial Buildings

  • Retail facilities
  • Commercial complexes
  • Service areas

Parking Structures

  • Multi-level parking areas
  • Vehicle storage zones

Public Infrastructure

  • Airports
  • Railway stations
  • Government buildings

Specialized Installations

  • Exposed ceiling applications
  • Open-structure buildings
  • Utility service areas

8. Certifications & Testing

Hydraulic Testing

Each sprinkler undergoes pressure testing for:

  • Structural integrity
  • Reliable performance
  • Operational safety

Quality Assurance

The sprinkler is subjected to:

  • Thermal activation verification
  • Pressure testing
  • Manufacturing quality inspections

Standards Compliance

  • Designed for automatic sprinkler systems.
  • Suitable for fire safety installations.

9. Installation Guidelines

Recommended Locations

  • Exposed piping systems
  • Warehouses
  • Industrial facilities
  • High-ceiling environments

Installation Benefits

  • Efficient coverage
  • Flexible system design
  • Reliable automatic protection

10. Warranty

ParameterDetails
Warranty Period12 Months
CoverageManufacturing Defects
Operational ReliabilityCovered
Material DefectsCovered

Warranty Exclusions

  • Improper installation
  • Mechanical damage
  • Unauthorized modifications
  • Non-standard operating conditions

Key Benefits

Automatic Fire Protection

  • Heat-activated operation.
  • Immediate response to fire conditions.

Ideal for Exposed Piping

  • Designed for upright installation.
  • Suitable for industrial environments.

Reliable Performance

  • Precision thermal activation.
  • Consistent water discharge.

Durable Construction

  • Corrosion-resistant materials.
  • Long service life.

Multiple Temperature Ratings

  • Flexible fire protection solutions.
  • Suitable for diverse applications.

Company Information

Palladium Safety Solutions Pvt. Ltd.
ISO 9001:2015 Certified Company

Locations

  • Delhi
  • Gurugram
  • Chennai
explore-business icon

Have questions?

We will be happy to help you. Please, fill this small form and help our customer support manager to contact you with all the details.

Take action

Browse our range, explore partnership opportunities, or request a call-back from our team.

grid image