The PALEX Upright Type Sprinkler is an automatic fire suppression device designed for installation above branch piping, with the deflector positioned upward. It is specifically engineered for areas with exposed piping systems, high ceilings, warehouses, industrial facilities, and locations where ceiling-mounted pendent sprinklers are not practical.
Manufactured using high-quality corrosion-resistant materials and equipped with a heat-sensitive glass bulb, the upright sprinkler automatically activates when the surrounding temperature reaches its rated value. The upward-facing deflector distributes water in a carefully engineered spray pattern, ensuring effective fire suppression and protection of the designated coverage area.
The sprinkler is suitable for industrial buildings, warehouses, factories, commercial facilities, storage areas, parking structures, and other fire protection applications requiring dependable automatic fire suppression.
Speak to our fire safety expert to learn more about this product.
| Parameter | Details |
|---|---|
| Manufacturer | Palladium Safety Solutions Pvt. Ltd. |
| Brand | PALEX |
| Product Type | Upright Type Sprinkler |
| Installation Type | Upright Mounted |
| Application | Automatic Fire Suppression Systems |
| Component | Specification |
|---|---|
| Body Material | Carbon Steel |
| Thermal Element | Heat-Sensitive Glass Bulb |
| Thread Type | NPT –" or R –" |
| Surface Finish | Corrosion-Resistant Coating |
| Deflector Type | Upright Water Distribution Deflector |
| Parameter | Details |
|---|---|
| Operating Temperature Range | 57°C to 260°C |
| Response Type | Standard Response / Quick Response |
| Operating Pressure | 12 Bar |
| Maximum Service Pressure | 175 PSI (12.07 Bar) |
| Thread Size | NPT –" or R –" |
| Installation Orientation | Upright |
| Glass Bulb Type | Colour-Coded Thermal Bulb |
| Temperature | Bulb Colour |
|---|---|
| 57°C | Orange |
| 68°C | Red |
| 79°C | Yellow |
| 93°C | Green |
| 141°C | Blue |
| 182°C | Mauve |
| 260°C | Black |
| Parameter | Details |
|---|---|
| Hydraulic Pressure Capacity | Up to 175 PSI |
| Activation Response | Fast Thermal Activation |
| Spray Pattern | Uniform Upright Distribution |
| Heat Detection Accuracy | High Precision |
| Corrosion Resistance | Excellent |
| Service Life | Long-Term Use |
The sprinkler helps:
Provides:
Supports:
Each sprinkler undergoes pressure testing for:
The sprinkler is subjected to:
| Parameter | Details |
|---|---|
| Warranty Period | 12 Months |
| Coverage | Manufacturing Defects |
| Operational Reliability | Covered |
| Material Defects | Covered |
Palladium Safety Solutions Pvt. Ltd.
ISO 9001:2015 Certified Company
| Parameter | Details |
|---|---|
| Body Material | Carbon Steel |
| Thermal Element | Heat-Sensitive Glass Bulb |
| Thread | NPT –" or R –" |
| Response Type | Standard / Quick Response |
| Operating Pressure | 12 Bar |
| Max Service Pressure | 175 PSI (12.07 Bar) |
| Temperature Range | 57°C to 260°C (colour-coded bulbs) |
| Installation | Upright |
| Warranty | 12 Months (Manufacturing Defects) |
Drag to pan · Scroll or pinch to zoom · +/- buttons · Arrow keys to move
Could not display this PDF in the browser.
An Upright Type Sprinkler is an automatic fire sprinkler installed above branch piping with the deflector facing upward.
The sprinkler activates when the glass bulb reaches its rated temperature and releases water through the upward deflector.
They are commonly installed in warehouses, industrial buildings, factories, and exposed ceiling applications.
Upright sprinklers are ideal where piping is exposed or where ceiling-mounted sprinklers are not practical.
The sprinkler body is manufactured from corrosion-resistant carbon steel.
The sprinkler uses a heat-sensitive glass bulb.
Available ratings include:
Bulb colours indicate the sprinkler's activation temperature.
The sprinkler is available with:
thread connections.
The deflector distributes water evenly across the protected area for effective fire suppression.
Yes. Both standard response and quick response models are available.
Quick response sprinklers activate faster and help improve fire control and occupant safety.
Yes. They are one of the most commonly used sprinkler types in warehouse applications.
Yes. They are specifically designed for industrial and manufacturing environments.
Yes. Upright sprinklers are ideal for exposed piping and open-ceiling designs.
No. Only sprinklers exposed to sufficient heat activate individually.
Inspections should be conducted according to fire safety maintenance schedules and standards.
No. Painting may interfere with sprinkler activation and water distribution.
Common sectors include:
Routine inspections should verify:
Yes. They can be easily integrated into existing exposed piping systems.
The warranty covers:
Because it offers:
Browse our range, explore partnership opportunities, or request a call-back from our team.
Fill in your details — we’ll call you back shortly. Fields marked * are required.