The PALEX Manual Abort Unit is a highly reliable and essential component in any conventional fire detection and alarm system. Designed to provide manual triggering of fire alarms, this unit can be activated in emergencies by simply pressing the center area, which breaks the glass film and completes the alarm circuit.
Widely used across commercial, industrial, and institutional infrastructures, the unit comes with a thin breakable glass layer, dual LED indicators, and a robust flame-retardant (FR) polymer housing. It ensures easy visibility, fast response, and high durability.
Speak to our fire safety expert to learn more about this product.
| Parameter | Details |
|---|---|
| Manufacturer | Palladium Safety Solutions Pvt. Ltd. |
| Trade Mark / Brand | PALEX |
| Type | Manual Abort Unit |
| Specification | Details |
|---|---|
| Operating Voltage | 20–26 VDC |
| Alarm Current | 30 mA |
| Flashing Type | Dual LED (Visual Indication During Alarm) |
| Weight | 150 gm |
| Dimensions | 85×85×50 mm |
| Color Options | Green (Abort), Yellow (Gas Release) |
| Glass Type | Thin Film – Breakable with Finger or Object |
| Mounting | Surface Mount (Wall Mounted) |
| Material of Construction | Flame Retardant (FR) Polymer Housing |
| Ingress Protection | IP42 (Indoor Use) |
| Operating Temperature | 0°C to +55°C |
| Storage Temperature | -10°C to +60°C |
| Relative Humidity | ?±95% RH (Non-Condensing) |
| Wiring Terminals | Screw-Type, Pre-Wired Connector Block |
The Manual Abort Unit operates within a voltage range of 20–26 VDC, making it suitable for integration with conventional fire alarm and suppression systems.
The device consumes 30 mA during alarm activation, ensuring reliable operation while maintaining system efficiency.
Dual LED flashing indicators provide clear visual confirmation whenever the unit is activated.
With dimensions of 85×85×50 mm, the unit offers a compact footprint for easy installation in commercial and industrial facilities.
Available in Green (Abort) and Yellow (Gas Release) options, enabling quick identification during emergency situations.
The activation mechanism uses a thin breakable film that can be easily triggered by pressing with a finger or suitable object.
Constructed from flame-retardant polymer material to provide enhanced durability and fire resistance.
The unit offers IP42-rated protection for indoor installations, helping protect internal components from dust and water droplets.
Used for manual alarm activation during fire emergencies.
Functions as an abort trigger unit for gas suppression release systems.
Provides emergency manual control functions in industrial facilities.
Supports safety systems protecting critical IT infrastructure.
Used in high-risk industrial environments requiring manual emergency intervention.
Suitable for schools, hospitals, shopping malls, offices, and other public facilities.
Install at an accessible height, typically between 1.2 and 1.4 meters from floor level.
Do not install near locations subject to excessive vibration or moisture.
Ensure correct wiring polarity when connecting the unit to the Fire Alarm Control Panel (FACP).
The glass film must be replaced after every manual activation to restore functionality.
Install with tamper-resistant screws to prevent unauthorized operation or accidental damage.
12 Months from the date of invoice.
Manufacturing defects and electronic component failures.
Physical damage, misuse, and unauthorized tampering are not covered under warranty.
| Specification | Details |
|---|---|
| Operating Voltage | 20–26 VDC |
| Alarm Current | 30 mA |
| Indication | Dual LED Flashing |
| Housing | Flame Retardant (FR) Polymer |
| Dimensions | 85×85×50 mm |
| Weight | 150 gm |
| Colors | Green (Abort), Yellow (Gas Release) |
| Ingress Protection | IP42 |
| Operating Temperature | 0°C to +55°C |
| Warranty | 12 Months |
Drag to pan · Scroll or pinch to zoom · +/- buttons · Arrow keys to move
Could not display this PDF in the browser.
A Manual Abort Unit is a safety device used to manually interrupt or abort fire suppression and alarm system operations during emergency situations.
It allows authorized personnel to manually stop or control a suppression system before discharge when necessary.
The unit activates when the breakable glass film is pressed or broken, completing the circuit and initiating the programmed action.
Yes, it includes dual LED flashing indicators for alarm status confirmation.
The housing is manufactured from Flame Retardant (FR) polymer material.
Yes, it is specifically designed for use with conventional fire alarm systems.
Yes, it functions as an abort trigger unit in gas suppression installations.
It is designed for surface wall mounting.
The unit is primarily designed for indoor applications.
Yes, it is commonly installed in server rooms and data centers.
Yes, it features a screw-type pre-wired connector block for easy installation.
The glass film should be replaced after every activation.
Browse our range, explore partnership opportunities, or request a call-back from our team.
Fill in your details — we’ll call you back shortly. Fields marked * are required.