We, Palladium Safety Solutions Pvt. Ltd., a leading manufacturer of Fire Alarm Systems, introduce the Response Indicator – a precision auxiliary device designed to complement automatic fire detection systems. This compact yet highly visible unit is engineered to quickly indicate the origin of an alarm signal from detectors located in concealed, restricted, or remote areas.
The Response Indicator is connected directly to a fire detector and features dual high-intensity LEDs that activate when the detector signals an alarm. This visual alert allows safety personnel to identify the exact location of the triggered detector with minimal delay, thus enabling faster evacuation and prompt intervention.
Speak to our fire safety expert to learn more about this product.
| Parameter | Details |
|---|---|
| Manufacturer | Palladium Safety Solutions Pvt. Ltd. |
| Trade Mark / Brand | PALEX |
| Type | Response Indicator |
| Specification | Details |
|---|---|
| Power Input | 12/24V AC |
| Current Consumption | 8 mA |
| Construction | Flame Retardant (FR) Polymer ABS Housing |
| Flashing Type | Dual LED Based |
| Weight | 25 gm |
| Dimensions | L 60 mm × Ø 36 mm × W 70 mm |
| Colour | White |
| Mounting Type | Surface Mount |
| Operating Temperature | -1°C to +55°C (Typical Indoor Conditions) |
The Response Indicator operates on a 12V AC or 24V AC power supply, making it compatible with a wide range of conventional fire alarm systems and detector networks.
Designed for energy-efficient operation, the unit consumes only 8 mA of current, ensuring minimal load on the connected fire detection system.
Manufactured using Flame Retardant (FR) Polymer ABS material, the housing provides enhanced durability, safety, and resistance to fire-related hazards.
The Response Indicator utilizes dual high-intensity LEDs that provide clear visual confirmation whenever the connected detector enters an alarm condition.
With a weight of only 25 grams and compact dimensions, the indicator can be installed easily in confined spaces and concealed locations.
The surface-mounted design enables quick installation and easy integration with existing fire alarm wiring systems.
The indicator operates effectively in temperatures ranging from -1°C to +55°C, making it suitable for typical indoor commercial and industrial environments.
Provides clear, high-brightness indication of detector activation.
LEDs illuminate the moment the connected detector signals an alarm.
Ideal for narrow spaces like false ceilings, shafts, and concealed zones.
Efficient operation ensures minimal load on the fire alarm system.
Flame-retardant ABS polymer housing ensures long-term use under varying conditions.
Works with a wide range of conventional detectors operating on 12/24V AC systems.
Fixed with front screws for secure mounting and maintenance prevention.
Can be seamlessly installed in both new and retrofitted alarm systems.
Requires minimal depth for mounting and connects easily to the existing wiring network.
Designed to meet fire safety and signalling norms for commercial and residential installations.
Detectors mounted in hidden areas can be easily identified through the visible indicator.
Helps pinpoint activated detectors in restricted or sensitive zones.
Minimizes disruption by visually signalling detector activation in cleanroom or controlled environments.
Suitable for malls, hotels, office buildings, and commercial complexes where detectors are installed in concealed locations.
Ideal for warehouses, manufacturing plants, factories, and facilities with complex ceiling layouts.
Enhances alarm visibility in low-light and enclosed environments.
Ensures quick response in schools, colleges, classrooms, and corridors with limited detector accessibility.
Helps maintenance and security personnel quickly trace alarm origins in shared and concealed spaces.
Palladium Safety Solutions Pvt. Ltd. offers a One-Year Limited Warranty on the Response Indicator.
This warranty covers defects in material and workmanship under normal use and installation conditions. The warranty does not extend to damage caused by misuse, unauthorized modification, or electrical surges.
| Specification | Details |
|---|---|
| Power Input | 12/24V AC |
| Current Consumption | 8 mA |
| Construction | Flame Retardant ABS Housing |
| Indication | Dual LED Based |
| Weight | 25 gm |
| Dimensions | L 60 mm × Ø 36 mm × W 70 mm |
| Colour | White |
| Mounting | Surface Mount |
| Operating Temperature | -1°C to +55°C |
| Warranty | 1 Year Limited |
Drag to pan · Scroll or pinch to zoom · +/- buttons · Arrow keys to move
Could not display this PDF in the browser.
A Response Indicator is a visual alarm device that helps identify the exact location of a fire detector that has been activated.
The device connects directly to a fire detector and activates its LEDs when the detector enters an alarm condition.
It helps maintenance teams and emergency responders quickly locate activated detectors installed in concealed or difficult-to-access areas.
It uses dual high-intensity LEDs for bright and visible alarm indication.
Yes, it is specifically designed to work alongside fire alarm detectors and fire detection systems.
Yes, it is compatible with a wide range of conventional detectors operating on 12/24V AC systems.
The housing is made from Flame Retardant (FR) ABS polymer.
Yes, it is commonly installed to indicate alarms from detectors located above false ceilings.
Yes, it helps identify activated detectors in server rooms, data centers, and IT panels.
The device uses a surface-mount installation design.
Yes, it features a tamper-resistant design with secure front screw mounting.
Yes, it can be integrated into both new and retrofitted fire alarm systems.
It is commonly installed in hospitals, commercial buildings, industrial facilities, parking areas, educational institutions, and residential towers.
Yes, it is designed to meet industry fire safety and signalling requirements.
Browse our range, explore partnership opportunities, or request a call-back from our team.
Fill in your details — we’ll call you back shortly. Fields marked * are required.