Palex

The PALEX Hydrant Landing Valve – Gun Metal is a critical component of fire hydrant systems, designed to control and regulate the flow of water from hydrant risers to firefighting hoses during emergency operations. Manufactured from premium-grade Gun Metal (LTB-2), the landing valve provides exceptional corrosion resistance, durability, and long-term operational reliability.

Designed in accordance with IS 5290, the valve is suitable for installation in wet riser systems, fire hydrant networks, industrial fire protection systems, commercial buildings, residential high-rises, airports, hospitals, and public infrastructure projects. The valve enables firefighters to quickly connect hoses and access water during firefighting operations, ensuring efficient fire suppression and emergency response.

Speak to our fire safety expert to learn more about this product.

Product Description

1. General Data

ParameterDetails
ManufacturerPalladium Safety Solutions Pvt. Ltd.
BrandPALEX
Product TypeHydrant Landing Valve
MaterialGun Metal
StandardIS 5290
ApplicationWet Riser & Hydrant Systems

2. Technical Specifications

ParameterDetails
Body MaterialGun Metal (LTB-2)
Material StandardIS 318
Inlet Size80 mm Flanged
Outlet Connection63 mm Instantaneous Female Outlet
Working Pressure16 kg/cm²
Hydraulic Test Pressure24 kg/cm²
Valve TypeScrew Down Type
Hand Wheel MaterialCast Iron
Surface FinishPolished Gun Metal

3. Material Construction

Valve Body

The landing valve body is manufactured using:

  • Premium Gun Metal (LTB-2)
  • Precision-cast construction
  • Corrosion-resistant alloy composition
  • Heavy-duty firefighting design

This ensures reliable operation and long service life.

Internal Components

The valve incorporates:

  • High-quality spindle mechanism
  • Durable sealing arrangement
  • Smooth operating system
  • Reliable shut-off performance

Hand Wheel

The cast iron hand wheel provides:

  • Easy valve operation
  • Strong grip
  • Long-term durability
  • Reliable control during emergencies

4. Performance Specifications

ParameterDetails
Working Pressure16 kg/cm²
Hydrostatic Test Pressure24 kg/cm²
Water Flow PerformanceHigh Capacity
Corrosion ResistanceExcellent
Operational ReliabilityHigh
Service LifeLong-Term Use

5. Key Features

IS 5290 Compliance

  • Manufactured according to Indian Standards.
  • Suitable for fire hydrant systems.
  • Trusted firefighting performance.

Durable Gun Metal Construction

  • Excellent corrosion resistance.
  • Long operational lifespan.
  • Reliable performance in harsh environments.

High Pressure Capability

  • Designed for firefighting water systems.
  • Suitable for high-pressure applications.
  • Reliable water delivery.

Smooth Valve Operation

  • Easy hand wheel control.
  • Fast opening and closing.
  • Efficient firefighting support.

Leak-Resistant Performance

  • Secure sealing mechanism.
  • Reliable shut-off capability.
  • Reduced water loss.

Low Maintenance Design

  • Durable materials.
  • Long-term performance.
  • Reduced servicing requirements.

6. Performance Benefits

Efficient Firefighting Water Supply

The landing valve enables:

  • Rapid hose connection
  • Reliable water access
  • Effective firefighting operations

Corrosion Protection

Gun Metal construction resists:

  • Moisture
  • Rust
  • Environmental exposure
  • Long-term wear

Operational Reliability

Provides:

  • Consistent water flow
  • Secure operation
  • Dependable emergency performance

7. Applications

Fire Hydrant Systems

  • Wet riser systems
  • Building hydrants
  • Fire protection networks

Commercial Buildings

  • Office complexes
  • Shopping malls
  • Hotels
  • Business centers

Industrial Facilities

  • Manufacturing plants
  • Warehouses
  • Chemical industries
  • Refineries

Residential Buildings

  • High-rise apartments
  • Residential towers
  • Housing societies

Healthcare Facilities

  • Hospitals
  • Medical centers
  • Clinics

Public Infrastructure

  • Airports
  • Metro stations
  • Railway stations
  • Government facilities

8. Installation Guidelines

Recommended Installations

  • Wet riser systems
  • Staircase landing areas
  • Firefighting risers
  • Hydrant stations

Installation Benefits

  • Immediate firefighting access
  • Improved emergency response
  • Reliable water delivery

9. Maintenance Requirements

Routine Inspection

  • Check valve operation.
  • Inspect sealing condition.
  • Verify outlet integrity.

Preventive Maintenance

  • Clean valve assembly.
  • Lubricate moving parts.
  • Inspect for corrosion.

Periodic Testing

  • Water flow testing
  • Pressure testing
  • Leak verification

10. Warranty

ParameterDetails
Warranty Period12 Months
CoverageManufacturing Defects
Material DefectsCovered
WorkmanshipCovered

Warranty Exclusions

  • Improper installation
  • Physical damage
  • Unauthorized modifications
  • Negligence

Key Benefits

Reliable Fire Protection

  • Immediate water access.
  • Efficient firefighting support.

Durable Construction

  • Premium Gun Metal body.
  • Long service life.

Corrosion Resistance

  • Suitable for demanding environments.
  • Excellent durability.

IS Standard Compliance

  • Manufactured according to IS 5290.
  • Trusted performance.

Easy Operation

  • Smooth hand wheel control.
  • Fast emergency deployment.

Company Information

Palladium Safety Solutions Pvt. Ltd.
ISO 9001:2015 Certified Company

Locations

  • Delhi
  • Gurugram
  • Chennai
explore-business icon

Have questions?

We will be happy to help you. Please, fill this small form and help our customer support manager to contact you with all the details.

Take action

Browse our range, explore partnership opportunities, or request a call-back from our team.

grid image