The Flame Proof Manual Call Point is a robust and reliable emergency signalling device specifically engineered for use in hazardous areas where explosive atmospheres may be present. It is designed to prevent the ignition of surrounding explosive gases or dust by containing any sparks or flames within its flameproof enclosure.
Upon manual activation–typically by breaking the glass or pressing the emergency button–it sends a signal to the fire alarm control panel, initiating the fire alarm system. This immediate response mechanism is critical in industrial environments to ensure timely evacuation and fire-fighting measures.
Speak to our fire safety expert to learn more about this product.
| Parameter | Details |
|---|---|
| Manufacturer | Palladium Safety Solutions Pvt. Ltd. |
| Trade Mark / Brand | PALEX |
| Type | Flame Proof Manual Call Point |
| Specification | Details |
|---|---|
| Operation Type | Manual |
| Colour | Red |
| Installation Height | Recommended at 1.4 Meters Above Floor Level |
The Flame Proof Manual Call Point is designed for manual emergency alarm activation in hazardous industrial environments. Its bright red colour ensures maximum visibility, while the recommended installation height of 1.4 meters allows quick access during emergency situations. This device serves as a critical component in fire alarm and emergency shutdown systems across high-risk industries.
| Specification | Details |
|---|---|
| Power Input (I/P) | 24 V DC |
| Electrical Contact | 1 NO (Normally Open) & 1 NC (Normally Closed) |
Operating on a 24V DC power supply, the Flame Proof Manual Call Point is designed for seamless integration with fire alarm control panels and emergency warning systems. The inclusion of both normally open and normally closed contacts provides installation flexibility and compatibility with a wide range of industrial fire protection systems.
| Specification | Details |
|---|---|
| Housing Material | Aluminium Casted (Red Coated) |
| Enclosure Type | Suitable for Hazardous Locations |
| Mounting | Wall Mounted |
| Hammer | Metal Hammer with Chain for Emergency Use |
Manufactured from high-strength cast aluminium and finished with a durable red coating, the Flame Proof Manual Call Point is built to withstand harsh industrial environments. The integrated emergency hammer with chain ensures rapid activation during critical incidents while maintaining compliance with industrial safety standards.
| Specification | Details |
|---|---|
| Ingress Protection (IP) | IP65 |
| Environmental Use | Indoor and Outdoor Hazardous Areas |
| Temperature Range | Typically -20°C to +60°C |
| Explosion Protection | Flameproof Enclosure |
Designed for hazardous and explosive environments, the device features IP65 protection against dust ingress and water jets. Its flameproof enclosure prevents ignition of surrounding gases or dust particles, making it ideal for oil and gas facilities, chemical plants, fuel terminals, and other high-risk locations. The wide operating temperature range ensures dependable performance in extreme conditions.
Enclosure designed to withstand internal explosions without causing ignition externally. The flameproof housing provides maximum safety in explosive atmospheres by containing sparks and internal explosions, preventing the spread of ignition to surrounding hazardous environments.
Total protection against dust ingress and low-pressure water jets from any direction. The IP65-rated enclosure ensures reliable operation in outdoor installations and harsh industrial conditions where dust, moisture, and contaminants are present.
Ensures high visibility in emergency situations. The highly visible red finish enables rapid identification during emergencies, helping personnel quickly locate and activate the alarm system.
Immediate manual initiation of alarm signal to fire panel. The device enables rapid alarm activation, improving response times and supporting timely evacuation procedures in hazardous environments.
Pressure die-cast aluminium alloy body ensures durability in industrial use. The rugged aluminium body provides excellent mechanical strength and long-term reliability even in demanding industrial operations.
Simplifies installation and ensures secure electrical connections. Pre-wired terminal arrangements reduce installation time and help ensure dependable electrical connectivity with fire alarm systems.
Epoxy powder-coated surface protects against chemical and environmental damage. The protective coating enhances durability and helps prevent corrosion caused by chemicals, humidity, and harsh environmental conditions.
Installed in hazardous zones where hydrocarbon gases are handled or processed. Flame proof manual call points are widely deployed in refineries, offshore platforms, gas processing facilities, and fuel handling stations where explosion risks exist.
Positioned near tank farms, pump houses, and processing units for emergency alarm activation. The device enables immediate emergency response in fuel storage and distribution facilities.
Used in solvent storage areas, mixing sections, and reactors where flammable vapours are present. Chemical processing facilities rely on flameproof alarm devices to enhance worker safety and emergency preparedness.
Installed in generator rooms, diesel storage zones, and control rooms for manual override. Power generation and energy facilities use flameproof manual call points as part of comprehensive fire protection systems.
Used in lithium-ion storage and charging rooms to manually trigger alarms during thermal events. The device provides a reliable emergency alarm solution for battery energy storage systems and charging infrastructure.
Positioned near mixing booths and spray chambers to meet fire safety codes.
Ideal for hazardous areas involving gas welding and flammable dust.
Industrial manufacturing facilities use flameproof manual call points to enhance safety in environments with combustible gases, dust, and vapours.
Used in dust-laden and potentially methane-rich environments.
Mining operations require explosion-protected emergency devices to improve worker safety and emergency response capabilities.
Installed at entry and exit points for rapid emergency alerting during fuel spills or ignition incidents.
Transportation and logistics facilities use flameproof alarm devices to protect personnel and infrastructure in hazardous operations.
Manual call points allow quick alarm triggering during gas leaks or chemical fires. Waste management facilities utilize flameproof emergency devices to address fire risks associated with combustible materials and hazardous gases.
12 Months from Date of Invoice
| Specification | Details |
|---|---|
| Power Input | 24 V DC |
| Contacts | 1 NO & 1 NC |
| Housing | Aluminium casted (red coated) |
| Mounting | Wall mounted |
| IP Rating | IP65 |
| Protection | Flameproof enclosure |
| Temperature | -20°C to +60°C (typical) |
| Installation Height | 1.4 m recommended |
| Warranty | 12 Months from invoice |
Drag to pan · Scroll or pinch to zoom · +/- buttons · Arrow keys to move
Could not display this PDF in the browser.
A Flame Proof Manual Call Point is an emergency fire alarm activation device specifically designed for hazardous and explosive environments.
It manually activates a fire alarm system by sending a signal to the fire alarm control panel when triggered.
Its specially engineered enclosure contains sparks and internal explosions, preventing ignition of surrounding explosive atmospheres.
The housing is manufactured from cast aluminium with a red protective coating.
Yes, it is suitable for both indoor and outdoor hazardous locations.
Yes, it is specifically designed for hazardous areas where explosive gases or dust may be present.
The device is supplied in bright red for high visibility.
Yes, a metal hammer with chain is provided for emergency activation.
Oil & gas, petrochemical, chemical processing, mining, power generation, and manufacturing industries.
Yes, it is ideal for petroleum refineries and fuel terminals.
Yes, it is designed for hazardous chemical processing environments.
Yes, it is suitable for lithium-ion battery storage and charging rooms.
IP65 protection prevents dust ingress and protects against water jets, ensuring reliable performance.
Aluminium provides durability, corrosion resistance, and mechanical strength.
Yes, the epoxy powder-coated finish protects against environmental and chemical damage.
Yes, it is suitable for underground mines and dust-prone environments.
Yes, it is designed for integration with fire alarm systems.
It improves safety by preventing ignition of hazardous gases and combustible dust.
It enables immediate emergency response and faster evacuation during critical incidents.
Browse our range, explore partnership opportunities, or request a call-back from our team.
Fill in your details — we’ll call you back shortly. Fields marked * are required.