The Public Addressable Panel is a fire alarm monitoring and emergency PA (Public Address) system designed for fire detection, zone-based alarm control, and emergency announcements. It integrates seamlessly with smoke detectors, heat detectors, manual call points, hooters, and sprinkler systems.
This expandable system supports 2 to 32 zones (customizable up to 50 zones) and offers real-time monitoring, live announcements, two-way communication, and external speaker connectivity. Equipped with an LCD display, LED indicators, and battery backup, the Public Addressable System ensures uninterrupted fire safety operations.
Speak to our fire safety expert to learn more about this product.
| Parameter | Details |
|---|---|
| Manufacturer | Palladium Safety Solutions Pvt. Ltd. |
| Trade Mark / Brand | PALEX |
| Type | Public Addressable System |
| Specification | Details |
|---|---|
| Input Power Supply | 230 V AC, 50Hz |
| Standby Power Supply | 24 V DC / 10 Amp |
| Battery Backup | 24V Rechargeable Battery (Not Included) |
| Battery Charger | Inbuilt with Auto Cut-Off |
| Battery Charging Current | 2A to 10A (Adjustable) |
| End of Line Resistor (EOLR) | 34 kΩ |
| Current Consumption | Customized |
| Power Protection | Fuse Protection (Overload & Short Circuit) |
Engineered for continuous fire safety operation with primary 230V AC supply and reliable 24V DC standby. Integrated battery charger with auto cut-off and fuse protection safeguards against overloads and short circuits.
| Specification | Details |
|---|---|
| Zone Capacity | 2 to 32 Zones (Expandable up to 50) |
| Detection Output Voltage | 24 V DC |
| Detector Compatibility | Smoke, Heat, Gas, Multi-Sensor Detectors |
| Hooter Output | 100V AC (Loud Emergency Siren) |
| Alarm Response Time | ≤ 3 Seconds |
| Fault Indication | Zone-Wise Fault LED + LCD Display |
| Annunciation Windows | Fire, Fault, Battery, AC Fail, Fuse Blown |
| Specification | Details |
|---|---|
| Microphone Type | Gooseneck Microphone (Wired) |
| Talkback Unit | Two-Way Communication |
| Speaker Connectivity | External PA Speaker Support |
| Amplifier Wattage | Customizable as per Requirement |
| Music Playback Support | Yes (Music Player Attachable) |
| Audio Output Control | Zone-Wise PA Announcements |
| Specification | Details |
|---|---|
| Display Type | 16×2 Character LCD |
| Zone Selector Switch | Yes (Individual Activation/Deactivation) |
| LED Status Indicators | Mains ON, AC Fail, Fuse Blown, Battery Low |
| Annunciation Windows | Fire, Fault, AC, Battery, Hooter |
| Specification | Details |
|---|---|
| Housing Material | Heavy-Duty MS Sheet (Powder Coated) |
| Colour | Red |
| Weight | Approx. 10–15 kg (Varies) |
| Mounting Type | Wall-Mounted / Surface Mount |
| Operating Temperature | -10°C to 55°C |
| Humidity Tolerance | Up to 95% RH (Non-Condensing) |
Supports fire detection networks with smoke, heat, gas, and multi-sensor detectors.
Broadcasts live and pre-recorded evacuation messages.
Ideal for factories, warehouses, manufacturing facilities, and chemical plants.
Suitable for offices, shopping malls, hotels, hospitals, schools, and theatres.
Used in airports, railway stations, bus terminals, and metro stations.
Perfect for hospitals, research laboratories, educational institutions, and emergency response centers.
1-Year Manufacturer Warranty
| Specification | Details |
|---|---|
| Zones | 2–32 (expandable up to 50) |
| Input Power | 230 V AC, 50Hz |
| Standby | 24 V DC / 10 Amp |
| EOL Resistor | 34 kΩ |
| Hooter Output | 100V AC |
| Alarm Response | ≤ 3 seconds |
| Display | 16×2 LCD |
| PA Features | Mic, talkback, external speakers, zone-wise PA |
| Housing | Powder-coated MS sheet, red |
| Operating Temperature | -10°C to 55°C |
| Warranty | 1 Year |
Drag to pan · Scroll or pinch to zoom · +/- buttons · Arrow keys to move
Could not display this PDF in the browser.
A Public Addressable Panel is a fire alarm monitoring and emergency communication system that combines fire detection, alarm control, and public address functionality.
The system supports smoke detectors, heat detectors, gas detectors, and multi-sensor detectors.
Yes, it includes a gooseneck microphone for live emergency and routine announcements.
Yes, it includes a talkback unit for two-way communication.
Yes, zone selector switches allow activation and deactivation of individual zones.
Yes, external PA speaker connectivity is supported.
Yes, a music player can be connected to the panel.
Yes, the system supports a 24V rechargeable battery backup.
Yes, an inbuilt charger with auto cut-off is provided.
Fire, fault, battery, AC fail, and fuse blown indications are provided.
Yes, it supports integration with automatic sprinkler control systems.
No, amplifier wattage can be customized according to project requirements.
The enclosure is manufactured from heavy-duty powder-coated MS sheet.
Yes, it supports wall-mounted and surface-mounted installation.
Industrial facilities, commercial buildings, healthcare institutions, transportation hubs, and educational campuses commonly use these systems.
Yes, it is specifically designed for emergency announcements and evacuation management.
Yes, zone-wise public address announcements are supported.
It improves emergency communication, fire monitoring, evacuation management, and overall life safety.
Browse our range, explore partnership opportunities, or request a call-back from our team.
Fill in your details — we’ll call you back shortly. Fields marked * are required.