The Palex 32-Zone Fire Alarm Control Panel is built with advanced microcontroller-based technology to provide precise monitoring and management of fire detection systems. Serving as the central control unit of a fire alarm system, it supports integration with smoke detectors, heat detectors, manual call points, gas leak detectors, sprinkler flow switches, and hooters.
Designed with scalability and flexibility in mind, the panel supports RS-485 communication for mimic and repeater panels, making it ideal for large and complex installations. Its user-friendly interface includes real-time LCD and LED indicators, zone isolation switches, potential-free contacts, and comprehensive alarm handling functions to ensure system reliability and ease of maintenance.
Speak to our fire safety expert to learn more about this product.
| Parameter | Details |
|---|---|
| Manufacturer | Palladium Safety Solutions Pvt. Ltd. |
| Trade Mark / Brand | PALEX |
| Type | Conventional Fire Alarm Panel – 32 Zone |
| Number of Zones | 32 (Expandable in 8-Zone Increments) |
| System Compatibility | 2-Wire Configuration with Conventional Detectors |
| Specification | Details |
|---|---|
| Input Voltage | AC 220V ±10%, 50Hz |
| Internal DC Supply | Regulated DC 24V / 5A |
| Hooter Output | 4A @ 24V DC |
| End of Line Resistor | 4.7k Ohm Per Zone |
| Power Supply Features | Built-in Power Supply with Automatic Trickle and Fast Battery Charging |
| Battery Compatibility | 2×12V Sealed Lead Acid Batteries (Not Included) |
| Protection | Fuse and Reverse Polarity Protection |
The panel operates on a stable 220V AC power source and provides a regulated 24V DC supply for system devices and alarm accessories.
A dedicated 4A output supports multiple hooters and alarm notification devices.
Automatic trickle and fast charging functions ensure reliable battery backup performance.
Integrated fuse and reverse polarity protection help safeguard the panel from electrical faults.
| Specification | Details |
|---|---|
| Operating Temperature | 0°C to +55°C |
| Storage Temperature | -10°C to +60°C |
| Operating Humidity | Up to 95% RH (Non-Condensing) |
| Installation Environment | Indoor, Clean, Dry, and Well-Ventilated Area |
Designed to perform reliably in various environmental conditions while maintaining system stability.
Optimized for installation in secure indoor locations with adequate ventilation.
| Specification | Details |
|---|---|
| Dimensions (H × W × D) | 345×420×122 mm |
| Weight | Approximately 11 kg |
| Construction Material | 1.8mm CRCA Sheet, Powder Coated |
| Enclosure Colour | Red |
| Mounting Type | Surface Wall Mounted |
Manufactured using 1.8mm CRCA sheet with powder coating for durability and corrosion resistance.
Designed for secure wall-mounted installation in control rooms and monitoring areas.
| Specification | Details |
|---|---|
| Zone LED Indications | Fire, Open Circuit, and Short Circuit Status |
| Zone Test Facility | Individual Zone Testing for Fire, Open, and Short Conditions |
| Zone Isolation | Switch-Based Isolation Per Zone |
| Zone-Wise Hooter Support | Dedicated Output Available for Specific Zone Alerting |
| Fault Annunciation | Common Fault LED + Buzzer |
| Fire Annunciation | Common Fire LED + Hooter Trigger |
| Controls | Reset, Alarm Silence, Lamp Test, Zone Test, Zone Isolate |
Each zone includes dedicated LED indications for fire, open circuit, and short circuit conditions.
Individual zones can be isolated during maintenance, testing, or troubleshooting.
Dedicated zone-wise hooter outputs support targeted alarm notification.
| Specification | Details |
|---|---|
| LCD Display | 16×2 Alphanumeric LCD |
| LED Indicators | AC Mains, Battery Low, AC Fail, Charging, Reverse, Fire, Fault |
| Control Buttons | Membrane-Type Tactile Keys |
| Internal Buzzer | Fire and Fault Alert Indication |
The 16×2 LCD display provides instant notification of system events and alarm conditions.
LED indicators continuously display power, battery, fire, and fault status information.
Membrane-type keys simplify operation and system management.
| Specification | Details |
|---|---|
| Repeater Panel Interface | RS-485 Communication Port |
| Mimic Panel Interface | RS-485 Supported |
| Dry Contacts | Potential-Free NO/NC Contacts for Fire & Fault Relay Integration |
| Detector Compatibility | Supports Conventional Ionization, Photoelectric, and Heat Detectors |
Supports reliable communication with repeater and mimic panels for large-scale installations.
Potential-free relay contacts allow integration with building management and monitoring systems.
Compatible with a wide range of conventional fire detection devices.
12 Months from the Date of Invoice
| Specification | Details |
|---|---|
| Zones | 32 (expandable in 8-zone increments) |
| Input | AC 220V ±10%, 50Hz |
| DC Supply | 24V / 5A regulated |
| Hooter Output | 4A @ 24V DC |
| EOL Resistor | 4.7k × per zone |
| Battery | 2×12V SLA (not included) |
| Display | 16×2 LCD |
| Communication | RS-485 (mimic/repeater) |
| Dimensions | 345×420×122 mm |
| Weight | ~11 kg |
| Warranty | 12 Months from invoice |
Drag to pan · Scroll or pinch to zoom · +/- buttons · Arrow keys to move
Could not display this PDF in the browser.
A 32 Zone Fire Alarm Panel is a centralized fire detection and monitoring system capable of supervising 32 independent fire alarm zones.
It monitors fire detection devices, processes alarm signals, and activates notification devices during emergencies.
The panel supports smoke detectors, heat detectors, manual call points, gas detectors, and sprinkler flow switches.
Yes, it supports two 12V sealed lead-acid batteries.
Yes, each zone can be individually isolated using dedicated switches.
Yes, RS-485 communication is available for mimic and repeater panel connectivity.
Yes, potential-free relay contacts enable external system integration.
The panel includes fuse protection and reverse polarity protection.
Yes, every zone includes dedicated testing functionality.
Yes, it is designed for commercial, industrial, residential, and institutional applications.
Ionization, photoelectric, and heat detectors are supported.
Yes, it continuously monitors fire, fault, open circuit, and short circuit conditions.
Yes, additional zones can be added in 8-zone increments.