The Fire Alarm Panel – 10 Zone is a microcontroller-based conventional fire alarm panel designed to monitor and display the status of 10 independent fire detection zones through LCD and LED indications.
In the event of Fire, Fault, or Short Circuit conditions, the panel identifies the affected zone and performs the required actions such as activating common or zone-wise hooters. This latest technology fire alarm panel is specifically designed for commercial buildings and medium-scale industries where reliable fire monitoring and alarm management are essential.
Speak to our fire safety expert to learn more about this product.
| Parameter | Details |
|---|---|
| Manufacturer | Palladium Safety Solutions Pvt. Ltd. |
| Trade Mark / Brand | PALEX |
| Type | Conventional |
| Product Code | PSS-10Z |
Provides intelligent monitoring and reliable fire detection management. The microcontroller architecture enables fast event processing, accurate fault identification, and dependable performance in fire emergencies.
Displays system status, alarms, and fault information in real time. The LCD interface improves system visibility and helps operators respond quickly to fire incidents and maintenance requirements.
Multiple LED indicators provide complete system monitoring, ensuring operators can instantly identify power, battery, and fault conditions.
Dedicated LED indications for each zone. Zone-specific status indicators help maintenance personnel quickly identify the exact location of fire alarms and wiring faults.
Supports both zone-wise and common hooter operation. Flexible hooter control allows targeted alarm notification and improved emergency response management.
Allows isolation of individual zones through switches. Zone isolation simplifies maintenance and testing while keeping the remaining fire detection system operational.
Provides fire and fault relay outputs. Potential-free contacts allow integration with Building Management Systems (BMS), automation systems, and third-party monitoring equipment.
Easy-to-use control functions improve system management and operational efficiency.
Built-in battery charging support. The charging system ensures backup batteries remain fully charged and ready during power failures.
Compatible with any conventional detector. The panel works seamlessly with conventional smoke detectors, heat detectors, manual call points, and other fire detection devices.
Provides centralized notification for alarms and faults. The annunciation system ensures building operators receive immediate alerts during emergency events.
| Specification | Details |
|---|---|
| Mains Voltage | 220V AC |
| Frequency | 50 Hz |
| Power Consumption | 120 Watt (Fire Condition) |
| Operating Voltage | 24 V DC |
| Detection Output | 24 V DC |
| Hooter Output Supply | 24 V DC |
| Number of Relays | 14 |
The Fire Alarm Panel – 10 Zone operates on a standard 220V AC power supply and provides regulated 24V DC outputs for detectors and alarm devices. With 14 relay outputs, it offers versatile control and integration capabilities for fire alarm systems and building safety infrastructure.
| Specification | Details |
|---|---|
| Normal Operating Voltage | 16–24 V DC |
| Maximum Zone Resistance | 220 Ohms |
| End of Line (EOL) | 4k7 Ohm, 1 Per Zone |
| Standby Current | 200 mA |
The zone circuits are designed to provide stable monitoring and fault detection across all fire alarm zones. End-of-line monitoring ensures system integrity while minimizing false alarms and wiring issues.
| Specification | Details |
|---|---|
| Operating Temperature | 0°C to 55°C |
| Operating Humidity | 5% to 95% RH (Non-Condensing) |
The panel is designed to operate reliably across a wide range of environmental conditions, making it suitable for commercial, industrial, and institutional facilities.
| Specification | Details |
|---|---|
| Cabinet Type | CRCA with Powder Coated Finish |
| Colour | Caramel White |
| Dimensions | 345 mm × 420 mm × 122 mm |
| Approvals | CE |
| Maintenance Standard | As per IS 15908:2021 |
Manufactured using a durable powder-coated CRCA enclosure, the Fire Alarm Panel – 10 Zone provides long-lasting protection and compliance with recognized fire alarm maintenance standards.
| Item | Quantity |
|---|---|
| Fire Alarm Panel | 1 Nos |
| Specification | Details |
|---|---|
| Product Code | PSS-10Z |
| Zones | 10 |
| Mains | 220V AC, 50 Hz |
| Operating Voltage | 24 V DC |
| Hooter Output | 24 V DC |
| Relays | 14 |
| EOL Resistor | 4k7 per zone |
| Max Zone Resistance | 220 – |
| Standby Current | 200 mA |
| Display | 16×2 LCD |
| Dimensions | 345×420×122 mm |
| Approvals | CE |
| Standard | IS 15908:2021 |
Drag to pan · Scroll or pinch to zoom · +/- buttons · Arrow keys to move
Could not display this PDF in the browser.
A 10 Zone Fire Alarm Panel is a conventional fire alarm control unit designed to monitor and manage up to 10 independent fire detection zones.
The panel is compatible with all conventional fire detectors.
Yes, it supports conventional manual call points.
The panel provides Fire, Open Circuit, and Short Circuit indications.
Yes, each zone can be isolated using dedicated switches.
Yes, every zone has separate fire, open, and short circuit LED indications.
Yes, both common and zone-wise hooter functionality are available.
Yes, it includes both trickle charging and fast charging facilities.
Mains ON, AC Fail, Open, Fuse, Charging, Reverse Polarity, and Battery indications are provided.
Yes, potential-free contacts allow integration with external systems.
The cabinet is manufactured from powder-coated CRCA sheet.
Commercial buildings, educational institutions, warehouses, healthcare facilities, and medium-sized industrial units commonly use them.
Improved accuracy, faster response, better fault detection, and enhanced system reliability.
Browse our range, explore partnership opportunities, or request a call-back from our team.
Fill in your details — we’ll call you back shortly. Fields marked * are required.