Palex

The PALEX Sidewall Type Sprinkler is an advanced automatic fire suppression device designed to provide efficient and targeted water discharge in areas where ceiling-mounted sprinklers are impractical or undesirable. Installed along walls, the sprinkler distributes water in a specially engineered spray pattern that effectively protects adjacent areas while maintaining architectural flexibility.

Manufactured using high-quality carbon steel and equipped with a heat-sensitive glass bulb mechanism, the sprinkler activates automatically when surrounding temperatures reach its rated operating point. Available in multiple temperature ratings and response types, the Sidewall Type Sprinkler is widely used in residential buildings, hotels, hospitals, offices, retail spaces, educational institutions, and industrial facilities requiring reliable wall-mounted fire protection.

Speak to our fire safety expert to learn more about this product.

Product Description

1. General Data

ParameterDetails
ManufacturerPalladium Safety Solutions Pvt. Ltd.
BrandPALEX
Product TypeSidewall Type Sprinkler
Installation TypeWall Mounted
ApplicationAutomatic Fire Suppression Systems

2. Material & Construction Details

ComponentSpecification
Body MaterialCarbon Steel
Thermal ElementHeat-Sensitive Glass Bulb
Thread TypeNPT –" or R –"
Surface FinishCorrosion-Resistant Coating
Discharge PatternSidewall Water Distribution

3. Technical Specifications

ParameterDetails
Operating Temperature Range57°C to 260°C
Response TypeStandard Response / Quick Response
Operating Pressure12 Bar
Maximum Service Pressure175 PSI (12.07 Bar)
Thread SizeNPT –" or R –"
Installation OrientationHorizontal Sidewall
Glass Bulb TypeColour-Coded Thermal Bulb

Available Temperature Ratings

TemperatureBulb Colour
57°COrange
68°CRed
79°CYellow
93°CGreen
141°CBlue
182°CMauve
260°CBlack

4. Performance Specifications

ParameterDetails
Hydraulic Pressure CapacityUp to 175 PSI
Activation ResponseFast Thermal Activation
Spray CoverageOptimized Sidewall Coverage
Heat Detection AccuracyHigh Precision
Corrosion ResistanceExcellent
Service LifeLong-Term Use

5. Key Features

Wall-Mounted Design

  • Ideal where ceiling sprinklers cannot be installed.
  • Saves ceiling space.
  • Improves architectural flexibility.

Automatic Fire Detection

  • Heat-sensitive glass bulb operation.
  • Automatic activation during fire conditions.
  • No manual intervention required.

Precise Temperature Control

  • Colour-coded bulbs.
  • Accurate activation temperatures.
  • Multiple temperature options available.

Efficient Water Distribution

  • Optimized sidewall spray pattern.
  • Effective protection of adjacent areas.
  • Improved water utilization.

Durable Construction

  • Carbon steel body.
  • Corrosion-resistant finish.
  • Long operational life.

Flexible Installation

  • Compatible with standard sprinkler systems.
  • Suitable for new installations and retrofit projects.

6. Performance Benefits

Early Fire Suppression

The sprinkler helps:

  • Detect heat quickly
  • Suppress fires early
  • Minimize property damage

Enhanced Occupant Safety

Provides:

  • Automatic response capability
  • Improved evacuation time
  • Reduced fire spread

Reliable Fire Protection

Supports:

  • Continuous monitoring
  • Automatic activation
  • Consistent fire suppression performance

7. Applications

Residential Buildings

  • Apartments
  • Residential towers
  • Housing complexes

Commercial Buildings

  • Office spaces
  • Shopping centres
  • Hotels
  • Retail outlets

Healthcare Facilities

  • Hospitals
  • Clinics
  • Medical centres

Educational Institutions

  • Schools
  • Colleges
  • Universities

Industrial Facilities

  • Warehouses
  • Factories
  • Production units

Specialized Installations

  • Corridors
  • Hallways
  • Narrow spaces
  • Areas with architectural limitations

8. Certifications & Testing

Hydraulic Testing

Each sprinkler undergoes pressure testing to verify:

  • Structural integrity
  • Reliable performance
  • Operational safety

Quality Assurance

The sprinkler is subjected to:

  • Thermal activation testing
  • Pressure verification
  • Manufacturing quality checks

Standards Compliance

  • Designed to meet fire safety requirements.
  • Suitable for automatic sprinkler systems.

9. Installation Guidelines

Recommended Locations

  • Sidewall installations
  • Corridors
  • Hotel rooms
  • Office cabins
  • Residential units

Installation Benefits

  • Easier system design
  • Reduced ceiling modifications
  • Effective localized protection

10. Warranty

ParameterDetails
Warranty Period12 Months
CoverageManufacturing Defects
Operational ReliabilityCovered
Material DefectsCovered

Warranty Exclusions

  • Improper installation
  • Mechanical damage
  • Unauthorized modifications
  • Non-standard operating conditions

Key Benefits

Automatic Fire Protection

  • Heat-activated operation.
  • Immediate response to fire conditions.

Space-Saving Installation

  • Ideal for wall-mounted applications.
  • Suitable for architectural constraints.

Reliable Performance

  • Precision thermal activation.
  • Consistent water discharge.

Durable Construction

  • Carbon steel body.
  • Corrosion-resistant finish.

Multiple Temperature Ratings

  • Suitable for various operating environments.
  • Flexible fire protection design.

Company Information

Palladium Safety Solutions Pvt. Ltd.
ISO 9001:2015 Certified Company

Locations

  • Delhi
  • Gurugram
  • Chennai
explore-business icon

Have questions?

We will be happy to help you. Please, fill this small form and help our customer support manager to contact you with all the details.

Take action

Browse our range, explore partnership opportunities, or request a call-back from our team.

grid image