The Tube-Based Clean Agent Fire Suppression System is a highly specialised, automatic, and localised fire protection solution designed for enclosed electrical and electronic equipment. By using pressurised clean agents and advanced heat-sensitive pneumatic detection tubes, the system ensures fast, power-independent fire detection and suppression.

The system is ideal for mission-critical applications where equipment downtime and damage must be minimised. Designed for both retrofit and new installations, it is compatible with integrated control systems and capable of multi-zone protection.

  • Compact Design
  • Easy to install & Use
  • Resettable Power Function
  • It has a Test button to start a manual fire alarm
  • Silence button features on the panel for hooter silence
  • Flasher & Sounder system on the panel

Speak to our fire safety expert to learn more about this product.

Product Description

1. GENERAL DATA

ParameterDetails
ManufacturerPalladium Safety Solutions Pvt. Ltd.
Trade Mark/Brand"PALEX"
TypeTube Based Suppression System

2. SUPPRESSION AGENT

ParameterDetails
AgentFK-5-1-12
Chemical CompositionDodecafluoro-2-methylpentan-3-one
TypeClean Agent
ApplicationsClass A, B, C & Electrical Fires
Properties / RemarksNon-Conductive, Zero Residue, Safe for Electronics
Ozone Depletion Potential0.00
Atmospheric Lifetime5 Days
Global Warming Potential< 1
Boiling Point49°C
ToxicityApproved for occupied spaces (as per NFPA 2001)

3. SYSTEM CONFIGURATIONS

A. Direct System

  • Heat-sensitive pneumatic polymer tubing acts as both a linear heat detector and agent discharge line.
  • When exposed to flame or elevated temperature (110°C), the tube ruptures at the hottest point.
  • Clean agent is discharged directly through the burst opening, flooding the fire zone.
  • Ideal for small enclosures with single-point risk concentration.

B. Master Control Unit (MCU)

  • Provides electrical supervision, alarm activation, zone-based control, and user interface.
  • Includes fail-safe battery backup, sounder relays, and system health indicators.
  • Integrates with building fire alarm systems and SCADA/BMS systems.

4. COMPLETE SYSTEM COMPONENTS (WITH TECHNICAL DETAILS)

CYLINDER

ParameterDetails
MaterialSteel (CRCA), SS31L (Optional)
Volume2 kg, 4 kg & 6 kg
Working Pressure15 bar (FK-5-1-12)
Testing Pressure35 bar (LP systems)
FittingsM16×1.5 thread with O-ring sealing
MountingVertical wall bracket with anti-vibration clamps
FinishPowder coated RAL 3000, minimum 50 micron
AccessoriesSafety cap, label, tamper seal

DLP VALVE (DIRECT LOW PRESSURE)

ParameterDetails
MaterialChrome-Plated Brass or Nickel-Plated Brass
FunctionOpens on pressure drop caused by tube rupture
Connection PortsTube port: M10×1F or 1/4" NPT
Fill Port1/8" NPT (with stainless plug)
Pressure Gauge Port1/8" BSP/NPT
Pressure Switch Port1/8" NPT
Valve BodyMachined brass block, leak-tested to 50 bar
IncludesManual reset lever (optional), non-return valve mechanism

FIRETRACE DETECTION TUBING (FDT)

ParameterDetails
MaterialSpecial thermoplastic (nylon blend)
Outer Diameter6 mm or 8 mm
Wall Thickness1 mm typical
Burst Pressure≤ 75 bar
Burst Temperature110°C × 10°C
ColorRed (Standard), UV-resistant
Fittings CompatibilityFiretrace compression-style fittings only
CertificationUL 521 Listed

CONNECTORS AND FITTINGS

Straight Connector

  • Nickel-Plated Brass
  • 1/4" tube OD × M10×1 thread

Elbow Connector

  • 90– angled brass fitting
  • Swivel or fixed

Union Connector

  • Tube-to-tube brass coupler

End-of-Line Plug

  • Solid brass cap for terminal end

T-Connector

  • For multiple branches from same cylinder

Pressure Test Port Adapter

  • Used for nitrogen leak testing and commissioning

PRESSURE GAUGES

ParameterDetails
TypeBourdon tube
Dial Range0–25 bar
Dial Size1.5" or 2"
MountingAxial or radial (valve mounted)
MaterialSS case with polycarbonate window

PRESSURE SWITCH

ParameterDetails
TypeSPDT micro-switch, silver contacts
Activation Range60–80 psi
Electrical Rating1A @ 30VDC
EnclosureIP65 brass or stainless enclosure

END-OF-LINE ADAPTOR

ParameterDetails
FunctionSecure leak-proof termination of detection tube
MaterialSolid Brass or SS304
Thread TypeM10×1 internal or push-fit
SealingCompression ferrule and sealing cap
MountingPanel fixed or floating type
Use CasePressure sealing of final tubing branch in DLP system

MASTER CONTROL UNIT (MCU)

ParameterDetails
Input Supply220V AC, 50/60Hz
Output Supply24VDC stabilized, battery backup supported
Operating Voltage MCU5VDC
Battery Capacity1.85A Max discharge current
Relay OutputsFire, Fault, Alarm (NC, C, NO), 1A / 30VDC
Sounder Output0.75A Max
Fuse Ratings1A / 250V (glass type, 5×20mm)
Panel FunctionsReset, Silence, Test, Fire Drill
Status IndicatorsPower, Fault, Fire, Zone indicators
Enclosure TypeWall-mounted, lockable IP-rated steel enclosure

5. ENVIRONMENTAL SPECIFICATIONS

ParameterDetails
Operating Temperature Range-20°C to +60°C
Storage Temperature Range-30°C to +70°C
Humidity Tolerance5% to 95% RH, non-condensing
Vibration ResistanceConforms to IEC 60068 shock tests
IP RatingIP55 / IP66 based on installation

6. SYSTEM FEATURES

  • Power-Free Operation (Direct System): Operates entirely without electrical input, ideal for unattended or remote environments.
  • Rapid Detection & Suppression: Heat-sensitive tube reacts instantly and discharges agent within seconds.
  • Modular & Scalable Design: Suitable for single-enclosure or multi-zone protection.
  • Non-Conductive & Non-Corrosive Agent: Safe for electrical installations and electronics.
  • Zero Residue Suppression: No water or powder cleanup required.
  • MCU Integration: Supports monitoring, alarm outputs, SCADA/BMS interfacing, and testing.
  • Environmentally Responsible: Zero ozone depletion potential and very low global warming potential.

7. APPLICATION AREAS

  • Server racks
  • Telecom enclosures
  • Network nodes
  • Electrical panels (MCC, PDB, LDB, UPS banks)
  • CNC and VMC machines
  • Robotics panels
  • Solar energy systems
  • Battery energy storage systems
  • Defence electronics
  • Vehicle cabinets
  • ATMs
  • Ticketing machines
  • Self-service kiosks
  • Medical diagnostic cabinets
  • Fume hoods

8. SAFETY & HANDLING

  • Always use original PSS fittings and valves.
  • Cylinders must be sealed with caps during transport.
  • Only trained personnel may refill or inspect the system.
  • Keep away from direct sunlight and corrosive environments.
  • Do not kink or crush the Firetrace Detection Tubing (FDT).

9. COMPLIANCE AND STANDARDS

  • UL Recognized Detection Tubing
  • ERTL Certified Master Control Panel

10. MAINTENANCE & INSPECTION

Monthly

  • Visual inspection of tubing
  • Pressure gauge inspection
  • Tamper seal inspection

Semi-Annual

  • Weight verification
  • Pressure verification
  • FDT integrity inspection

Every 5 Years

  • Cylinder visual inspection
  • FDT visual inspection
  • Hydrostatic testing as per CE requirements

11. WARRANTY

  • System Warranty: 1 year on all components
  • Detection Tubing Life: 10 years under normal operating conditions

12. NOTES & WARNINGS

  • Never transport charged cylinders without safety plugs.
  • Do not kink or damage Firetrace tubing.
  • Install unit vertically and away from environmental hazards.
  • Installation and servicing should only be performed by trained personnel.

Company Information

Palladium Safety Solutions Pvt. Ltd.
An ISO 9001:2015 Certified Company

Email: customercare@palladiumss.com | Website: www.palladiumss.com

Locations:  Delhi | Gurugram | Chennai

explore-business icon

Have questions?

We will be happy to help you. Please, fill this small form and help our customer support manager to contact you with all the details.

Take action

Browse our range, explore partnership opportunities, or request a call-back from our team.

grid image