Palex

The 12-Zone Conventional Fire Alarm Control Panel is designed as the central controller for small to medium-sized fire detection and alarm systems. It is microcontroller-based and supports 2-wire compatible devices, providing reliable zone-wise monitoring and alert functions.

The panel is ideal for installations in commercial complexes, industrial facilities, and institutions where gas leak detection, manual pull stations, sprinkler monitoring, and bell circuits are necessary.

Speak to our fire safety expert to learn more about this product.

Product Description

1. General Data

ParameterDetails
ManufacturerPalladium Safety Solutions Pvt. Ltd.
Trade Mark / BrandPALEX
TypeConventional Fire Alarm Panel
Product CodePSS-12Z

2. Technical Specifications

2.1 Electrical Parameters

SpecificationDetails
Power SupplyAC 220V, 50Hz ±10%
Internal SupplyDC 24V, 5 Amp
Hooter Output4A @ 24V DC
Battery ChargingTrickle and Fast Charging Supported

Reliable Power Supply

The panel operates on AC 220V, 50Hz power and provides a regulated 24V DC internal supply for connected fire alarm devices.

High-Capacity Hooter Output

A dedicated 4A output supports hooters, bells, and emergency notification devices.

Intelligent Battery Charging

Built-in trickle and fast charging functionality ensure reliable backup battery maintenance.

2.2 Environmental Conditions

SpecificationDetails
Operating Temperature0°C to +50°C (32–F to 122–F)
Storage Temperature-10°C to +55°C (14–F to 131–F)
Operating HumidityUp to 95% RH, Non-Condensing

Stable Environmental Performance

Designed to operate reliably under varying temperature and humidity conditions commonly found in commercial and industrial environments.

2.3 Zone Circuit Configuration

SpecificationDetails
Number of Zones12
Wiring Type2-Wire
EOL Resistance4.7k Ohm, One Per Zone
Zone Fault IndicationLED for Fire, Open, and Short Conditions
Zone TestingIndividual Zone-Wise Testing Supported
Zone IsolationSwitch-Based Isolation Per Zone
Detector CompatibilityWorks with Any Conventional Detector

12 Independent Monitoring Zones

The panel supports 12 separate zones for organized fire detection and alarm management.

Zone Fault Monitoring

Dedicated LED indicators provide visual identification of fire, open-circuit, and short-circuit conditions.

Zone Testing Facility

Each zone can be tested individually, simplifying maintenance and troubleshooting.

Zone Isolation Function

Specific zones can be isolated during servicing without affecting the operation of other zones.

Universal Detector Compatibility

The panel works with most standard conventional fire alarm detectors and initiating devices.

2.4 Mechanical & Physical Characteristics

SpecificationDetails
Construction MaterialCRCA Sheet, 1.8mm Thickness
FinishPowder Coated
ColourCaramel White
Dimensions (H × W × D)345 mm × 420 mm × 122 mm
WeightApproximately 7 kg

Durable Construction

Manufactured using 1.8mm thick CRCA sheet for enhanced durability and mechanical strength.

Powder-Coated Finish

Provides protection against corrosion and improves product lifespan.

Wall-Mounted Design

Compact dimensions and robust construction make the panel suitable for wall-mounted installations.

3. Key Features

  • Advanced Microcontroller-Based Design – reliable operation and quick alarm response.
  • 16×2 Character LCD Display – real-time alarms, faults, and system conditions.
  • LED Status Indicators – zone-wise fire, open, and short indication.
  • Zone-Wise Testing Capability – test individual zones without affecting the system.
  • Common and Zone-Wise Hooter Outputs – centralized and localized notification.
  • Multiple Power Fault Indications – mains, AC fail, fuse, charger, reverse battery, low battery.
  • Easy-to-Use Controls – Reset, Alarm Cancel, Lamp Test, and operational switches.
  • Battery Charging Facility – trickle and fast charging.
  • Common Fire and Fault Annunciation – centralized fire and fault indication.

4. Zone Control & Safety

  • Zone Isolation Switches – maintenance without interrupting the entire system.
  • Potential-Free Contacts – fire and fault signals for BMS and external devices.
  • End-of-Line Resistor Supervision – 4.7k × per zone for circuit supervision and fault monitoring.

5. Applications

  • Educational Institutions – schools, colleges, coaching centers, and training facilities.
  • Office Buildings – corporate offices, business centers, and commercial workplaces.
  • Small Industrial Units – workshops, production floors, machinery rooms, and manufacturing facilities.
  • Residential Complexes – apartment buildings, gated communities, and housing projects.
  • Commercial Complexes – shopping plazas, retail stores, standalone buildings, and small malls.

6. Warranty

Warranty Period

12 Months from the Date of Invoice

Coverage

  • Electrical Component Defects
  • Manufacturing Faults

Exclusions

  • Physical Damage
  • Misuse or Improper Handling
  • Water or Fire Damage
  • Unauthorized Modifications or Repairs